Escalator Moving Walk

Thông tin sản phẩm
Thông số kỹ thuật

Through years of experience in escalator technology, "Moving walk" has brought a sense of comfort to use.

The Toshiba Moving Walk carries passengers safely, quickly and comfortably as a means of transport for the new age.

Toshiba's escalators feature an energy-efficient drivetrain and quality operation with a simple design that provides a sense of relaxation and ease with a broad outlook.

Slope type

Flat ladder type:

 

Type

Width of footsteps (mm)

Tilt angle

Speed (m/ph)

Wattage (person/hour)

Height (mm)

Engine power (kw)

Heat generation (kJ/h)

 

 

S1000

ARC-12°-SD (slope type)

1000

12°

30

6000

3000 to 4220

5.5

3495

4247 to 5883

7.5

4765

5911 to 9015

Ask for Detail

S800

800

4800

3000 to 5550

5.5

3495

5578 to 5594

7.5

4765

S1000

ARC-0°-SD (flat type)

1000

6000

36310 trở xuống

5.5

3495

* The above application board is based on GB16899-2011.

* Moving walks with specifications other than those above, such as those with a speed of 40m/min or an incline not exceeding 12°, can also be supplied. For more details and specifications other than the standard, please contact Toshiba

General Specifications:

Category Assumption Optional specification
Application

Moving walk current TC

 

Controller type Single speed

Low speed automatic operation and stand-by stop (no pole type.) Optional specification.

Temperature

0℃ trở lên, 40℃ go down

 

Humidity

Monthly average 90% or less

Daily average 95% or less, No dewdrops

 

Source

For the main source: AC three phase. 380V-50Hz

AC ba pha. 380V-60Hz, AC.400V-50Hz, AC.415V-50Hz, AC.440V-50Hz

To illuminate: A phase  AC.220V-50Hz

* Note 1

AC một pha. 220V-60Hz, AC.230V-50Hz, AC.240V-50Hz

Voltage tolerance for mains

± 10% and below in the engine room terminal.

 

Voltage unbalance factor

5% go down

 

Frequency error

±5%

 

Voltage tolerance for lighting

±5% and below in the engine room terminal

 

Place of installation Covered indoor spots Outdoor type is not applicable
Corrosive gas Does not exist

* Note 2

Explosive gas Does not exist

 

Dust There must not be too much dust

0.3 mg/m3 go down

Effect on salt Does not exist

Amount of granulated sea salt NaCl 0,003mg / day / 100cm2 go down

Note 1: When supplying lighting and testing from the power source, a voltage-reducing transformer is required.

Note 2: SO3: 0.02mg/day/100cm2 or less, NO2: 0.02mg/100cm2 or less, Cl: 0.006mg/day/100cm2 or less, NH4+: 0.02mg/day/100cm2 or less.