Toshiba's escalators feature an energy-efficient drivetrain and quality operation with a simple design that provides a sense of relaxation and ease with a broad outlook.
Slope type
Flat ladder type:
Type |
Width of footsteps (mm) |
Tilt angle |
Speed (m/ph) |
Wattage (person/hour) |
Height (mm) |
Engine power (kw) |
Heat generation (kJ/h) |
|
|
|
|||||||
S1000 |
ARC-12°-SD (slope type) |
1000 |
12° |
30 |
6000 |
3000 to 4220 |
5.5 |
3495 |
4247 to 5883 |
7.5 |
4765 |
||||||
5911 to 9015 |
Ask for Detail |
|||||||
S800 |
800 |
4800 |
3000 to 5550 |
5.5 |
3495 |
|||
5578 to 5594 |
7.5 |
4765 |
||||||
S1000 |
ARC-0°-SD (flat type) |
1000 |
0° |
6000 |
36310 trở xuống |
5.5 |
3495 |
* The above application board is based on GB16899-2011.
* Moving walks with specifications other than those above, such as those with a speed of 40m/min or an incline not exceeding 12°, can also be supplied. For more details and specifications other than the standard, please contact Toshiba
General Specifications:
Category | Assumption | Optional specification |
Application |
Moving walk current TC |
|
Controller type | Single speed |
Low speed automatic operation and stand-by stop (no pole type.) Optional specification. |
Temperature |
0℃ trở lên, 40℃ go down |
|
Humidity |
Monthly average 90% or less Daily average 95% or less, No dewdrops |
|
Source |
For the main source: AC three phase. 380V-50Hz |
AC ba pha. 380V-60Hz, AC.400V-50Hz, AC.415V-50Hz, AC.440V-50Hz |
To illuminate: A phase AC.220V-50Hz * Note 1 |
AC một pha. 220V-60Hz, AC.230V-50Hz, AC.240V-50Hz |
|
Voltage tolerance for mains |
± 10% and below in the engine room terminal. |
|
Voltage unbalance factor |
5% go down |
|
Frequency error |
±5% |
|
Voltage tolerance for lighting |
±5% and below in the engine room terminal |
|
Place of installation | Covered indoor spots | Outdoor type is not applicable |
Corrosive gas | Does not exist |
* Note 2 |
Explosive gas | Does not exist |
|
Dust | There must not be too much dust |
0.3 mg/m3 go down |
Effect on salt | Does not exist |
Amount of granulated sea salt NaCl 0,003mg / day / 100cm2 go down |
Note 1: When supplying lighting and testing from the power source, a voltage-reducing transformer is required.